Large Flow Agricultural Irrigation Clean Double Suction Centrifugal Pump
We offer direct factory prices for all industrial water pumps, including multistage pumps, end suction pumps, slurry pumps, pipeline pumps, double-suction pumps, and submersible sewage pumps.
Every pump undergoes strict hydraulic testing and 100% manual quality inspection to ensure stable performance before delivery.
We provide customized pump solutions, including flow rate, head, power, voltage, flange size, materials, and application requirements.
All core engineering and production staff have more than 5 years of industry experience, ensuring stable processes and consistent pump quality across every batch.
Strong international logistics and supply chain support, able to deliver pumps quickly and safely to customers in 150+ countries.
MOQ = 1 piece for standard pumps, making sample testing, replacement, and small-batch orders easy and flexible.
ISO 9001 quality system + CE certification + SGS verification. Every pump is fully tested for pressure, sealing, and performance—delivering stable, durable, and trustworthy quality you can rely on.
This large-flow double suction centrifugal pump is designed for clean water irrigation, river water transfer, reservoir pumping, agricultural booster stations, and large-scale water supply projects. Its double-suction impeller and split-case structure help deliver stable high flow, balanced axial force, lower vibration, and easier maintenance for continuous irrigation and clean water transfer systems.
- Designed for large-flow clean water irrigation and water transfer
- Double-suction impeller helps balance axial thrust and reduce vibration
- Horizontal split-case structure allows easier inspection and maintenance
- Suitable for irrigation stations, reservoirs, river intake systems, and booster projects
- Flow, head, voltage, flange standard, material, and motor configuration can be customized
- Factory hydraulic testing and manual inspection before delivery
| Detailed parameters | |||
| Parameter | Specification | ||
| Product Type | Horizontal double suction centrifugal pump / split case pump | ||
| Main Application | Large-flow agricultural irrigation, clean water transfer, river intake, reservoir pumping, booster station | ||
| Suitable Liquid | Clean water or similar non-corrosive liquid without large solids | ||
| Flow Range | 180–288 m³/h for this model series; other flow ranges can be customized | ||
| Head Range | 82.5–100 m, depending on duty point | ||
| Pressure Range | 0.1–10 bar, depending on configuration | ||
| Inlet / Outlet Diameter | 125 mm or customized according to pipeline design | ||
| Connection Type | Flange connection | ||
| Flange Standard | DIN / ANSI / JIS / GB or customized | ||
| Seal Material | Carbon, ceramic, PTFE, stainless steel | ||
| Pump Material | Cast iron / stainless steel optional | ||
| Impeller Material | Cast iron / stainless steel / bronze optional according to water condition | ||
| Speed | 2950 r/min, depending on motor and frequency | ||
| Control Option | Manual operation or control cabinet optional | ||
| Motor Configuration | Electric motor; diesel engine configuration available for off-grid irrigation if required | ||
| Installation Type | Horizontal installation | ||
| Service | OEM / ODM / model selection support | ||
| Approx. Weight | Confirm according to final model and motor configuration | ||
For agricultural irrigation projects, pump selection should not be based only on outlet size. Required flow rate, total head, pipeline length, elevation difference, irrigation method, and daily operating hours should be confirmed before final model selection.
Product Description
This large-flow agricultural irrigation clean double suction centrifugal pump is engineered for clean water transfer projects where stable high flow, continuous operation, and easy maintenance are required. It is suitable for irrigation stations, farmland water supply, river and reservoir intake systems, regional water transfer, and booster pumping projects.
The double-suction impeller design allows water to enter the impeller from both sides. This helps balance axial thrust, reduce bearing load, lower vibration, and improve long-term operating stability. Compared with many single-suction centrifugal pumps, a double suction pump is often more suitable when the project requires larger flow capacity and continuous clean water delivery.
The horizontal split-case structure also improves maintenance convenience. Technicians can open the pump casing for inspection or component replacement without removing the entire pipeline system, which helps reduce downtime during irrigation seasons or continuous water supply operation.
For B2B buyers, the most important decision is not simply choosing a large pump. The correct model should match the required flow rate, head, water source, pipeline distance, pipe diameter, installation method, motor power, and operating schedule.
Key Advantages of Double Suction Pump
High-Flow, High-Efficiency Solution for Industrial & Municipal Water Systems
1. Balanced Axial Thrust for Extended Service Life
The double-suction impeller design naturally balances axial forces, minimizing bearing load, reducing vibration, and significantly extending the overall lifespan of critical components. This ensures long-term stability even during continuous 24/7 operation.
2. Hydraulically Optimized for Maximum Efficiency
Our pumps are engineered to achieve superior hydraulic efficiency, resulting in lower energy consumption and substantial operating cost savings. With a large flow capacity and smooth water passage, it stands out as an ultimate high-flow solution for municipal and industrial systems.
3. Easy Maintenance with Horizontal Split Case Structure
The horizontal split case allows technicians to open the casing without removing the pipelines, enabling quick inspection and replacement of impeller, seals, and bearings. This unique design reduces downtime and labor costs, improving plant operation efficiency.
4. Built for Harsh Environments & Long-Term Reliability
Constructed with high-grade materials and a reinforced heavy-duty structure, the pump delivers stable and uninterrupted water transfer performance. It is engineered for tough industrial conditions, severe climates, and demanding municipal applications.
Application Scenarios
This double suction split case pump offers the perfect combination of high flow performance, efficiency, durability, and ease of maintenance. For municipalities, industrial plants, and agricultural systems requiring stable, long-distance, and large-volume water transfer, it is a trusted and cost-effective solution.
-
Municipal Water Supply Systems
-
Transporting treated clean water from water plants to city pipeline networks
-
Regional water transfer projects & booster pump stations
-
Long-distance high-volume water delivery
Architecture & Urban Services
-
Circulating chilled water and cooling water for large commercial buildings
-
Core pump unit for high-rise fire-fighting systems
-
Urban drainage, flood control, and emergency discharge
Industrial Cooling & Process Systems
-
Cooling water circulation for thermal and nuclear power plants
-
Industrial process water transfer for petrochemical, steel, and energy industries
-
High-temperature or heavy-load cooling loop systems
Large-Scale Agricultural Irrigation
-
Extracting and delivering irrigation water from rivers or reservoirs
-
Supporting large farmlands that require continuous high flow
-
Ideal for irrigation station upgrades and new farmland projects
-
Scope of This Product
This section helps buyers confirm whether a double suction centrifugal pump is suitable for the real project. This product is mainly designed for clean water or similar non-corrosive liquid transfer. It is not intended for sewage, slurry, heavy sand water, or highly corrosive chemical liquids unless special configuration is confirmed.
| Working Condition | Suitability | Explanation |
| Large-flow clean water irrigation | Suitable | Designed for stable high-volume water transfer |
| River or reservoir water intake | Suitable with screening | Water should not contain large solids or heavy sand |
| Agricultural booster station | Suitable | Good for continuous flow and pressure support |
| Long-distance water transfer | Suitable with head calculation | Pipeline friction loss must be included |
| Municipal clean water supply | Suitable | Works well for treated or relatively clean water |
| Industrial cooling circulation | Suitable | Good for large-volume clean water circulation |
| Sewage water | Not suitable | Use a sewage pump for wastewater with solids |
| Slurry or muddy water | Not suitable | Use a slurry pump for abrasive particles |
| Corrosive chemical liquid | Not suitable by default | Requires material and seal confirmation |
| Small household irrigation | Usually oversized | Smaller end suction or pipeline pump may be more economical |
Why Choose a Double Suction Pump for Large-Flow Irrigation?
Large-scale irrigation projects often require stable high flow rather than only high pressure. A double suction centrifugal pump is suitable when the system needs to move a large amount of clean water continuously from rivers, reservoirs, canals, or storage tanks to irrigation networks.
Balanced Axial Thrust
The double-suction impeller allows water to enter from both sides, which helps balance axial forces. This can reduce bearing load, vibration, and mechanical stress during long-term operation.
Higher Flow Capacity
Double suction pumps are commonly selected for applications where a single-suction pump may be less efficient or mechanically stressed at the required flow rate.
Easier Maintenance
The split-case structure allows inspection of the internal components without fully removing suction and discharge pipelines. This is valuable for irrigation stations and water transfer projects where downtime must be minimized.
Stable Continuous Operation
For agricultural irrigation seasons, pump downtime can delay water delivery and affect project schedules. A properly selected double suction pump can support longer operating hours when matched with the correct duty point and motor configuration.
Double Suction Pump vs End Suction Pump vs Multistage Pump
Buyers often compare double suction pumps with end suction pumps and multistage pumps. The correct choice depends on whether the project needs high flow, high head, compact installation, or long-distance pressure boosting.
| Pump Type | Best For | Main Advantage | Limitation |
| Double Suction Pump | Large-flow clean water transfer and irrigation stations | High flow, balanced operation, easier maintenance | Larger footprint and higher initial cost |
| End Suction Pump | General water transfer and medium-flow systems | Simple structure, economical, easy to install | Less suitable for very large flow duties |
| Multistage Pump | High-head pressure boosting | Higher pressure in compact structure | Not always ideal for very high flow |
| Pipeline Pump | Inline circulation and building systems | Compact inline installation | Limited for large irrigation stations |
| Diesel Engine Pump | Off-grid irrigation and mobile water transfer | No grid power required | Fuel, noise, and engine maintenance |
For buyers comparing different pump types before final selection, this pump type comparison guide can help clarify when end suction, inline, and multistage pumps are more suitable than a large-flow double suction pump.
Recommended Applications
This double suction centrifugal pump is suitable for large-scale clean water transfer projects where stable flow, continuous operation, and maintenance access are important. It is commonly used in agricultural irrigation, municipal clean water supply, industrial cooling, and booster station projects.
Large-Scale Agricultural Irrigation
Used for transferring clean water from rivers, reservoirs, canals, or storage ponds to farmland irrigation networks. It is suitable for irrigation stations that require stable high flow and long daily operation.
River and Reservoir Water Intake
Suitable for clean or screened raw water intake projects. If the water contains sand, mud, or floating debris, buyers should add screening or filtration before the pump inlet.
Agricultural Booster Stations
Used to maintain flow and pressure in large irrigation pipeline systems, especially where farmland is distributed over a wide area or elevation changes are present.
Municipal Clean Water Supply
Suitable for treated water transfer, regional water supply, and large-volume clean water delivery where stable operation and maintainability are required.
Industrial Cooling Water Circulation
Can be used for industrial cooling loops, process water transfer, and clean water circulation systems where high flow and continuous operation are required.
Emergency or Seasonal Water Transfer
For seasonal irrigation or temporary high-volume water transfer, the pump can be configured with suitable motor or diesel engine options depending on site power conditions.
How to Select the Right Double Suction Pump Model
Selecting the right double suction centrifugal pump starts from the real working condition. Buyers should confirm flow rate, total head, pipe distance, water quality, installation method, motor power, and operating hours before choosing a model.
Step 1: Confirm Required Flow Rate
Flow rate decides how much water the pump can deliver per hour. For irrigation projects, flow should be estimated according to irrigation area, irrigation method, required water volume, and daily operating hours.
Step 2: Calculate Total Head
Total head is not only vertical height. It includes elevation difference, pipeline friction loss, outlet pressure, valve loss, elbow loss, and safety margin.
Total Head = Static Lift + Pipeline Friction Loss + Outlet Pressure Requirement + Safety Margin
If the pipeline is long, narrow, or includes many elbows and valves, the actual required head may be much higher than the visible elevation difference.
Step 3: Check Water Quality
This pump is mainly suitable for clean water or similar non-corrosive liquid. If river water contains sand, mud, grass, stones, or other solids, the inlet should use a screen or filtering structure. For muddy or abrasive water, a slurry pump may be more suitable.
Step 4: Match Motor Power
Motor power should match the duty point. Oversizing the motor may increase cost without improving real system performance, while undersizing may cause overload, unstable operation, or insufficient discharge.
Step 5: Confirm Installation and Maintenance Access
Double suction pumps are larger than many ordinary centrifugal pumps. Buyers should confirm foundation space, pipeline alignment, lifting space, maintenance access, and whether the pump casing can be opened conveniently.
Information Buyers Should Provide Before Quotation
To recommend the correct double suction pump model, buyers should provide working condition data before asking only for price. This helps avoid oversizing, insufficient head, high energy cost, and installation mismatch.
| Information Needed | Why It Matters |
| Required flow rate | Determines pump capacity |
| Required head | Determines pressure and motor power |
| Water source | River, reservoir, canal, tank, or treated water system |
| Water quality | Confirms whether clean water pump is suitable |
| Pipeline length | Affects friction loss |
| Pipe diameter | Affects velocity and pressure loss |
| Elevation difference | Affects static head |
| Irrigation method | Flood, sprinkler, drip, or booster station |
| Daily operating hours | Affects motor selection and durability |
| Voltage and frequency | Ensures electrical compatibility |
| Installation site | Indoor pump room, outdoor station, or field project |
| Destination country | Helps confirm standards, documentation, and logistics |
Related Products
About Customization
Engineering Configuration & Pump Selection Services
Every project has unique flow, head, and working conditions.
To help you get the right pump on the first try, LIQEN offers flexible configuration and technical support:
-
Customized Q/H combinations for different applications
-
Multiple voltage & frequency options
-
Material and flange customization
-
Optional motor upgrades (high-efficiency / explosion-proof)
-
Color & nameplate customization for distributors
-
Professional model selection with engineer support
-
MOQ 1 for sample testing and fast project validation
Customization Options for Irrigation and Water Transfer Projects
Different irrigation and clean water transfer projects may require different flow, head, material, motor, voltage, and connection standards. LIQEN Power can support customized configuration according to real working conditions and buyer requirements.
| Custom Option | Available Direction |
| Flow and Head | Selected according to duty point and pipeline system |
| Motor Power | Matched according to flow, head, voltage, and operating hours |
| Voltage and Frequency | 220V / 380V / 415V / 660V, 50Hz / 60Hz optional |
| Pump Material | Cast iron or stainless steel optional |
| Impeller Material | Cast iron, stainless steel, or bronze optional |
| Seal Material | Carbon, ceramic, PTFE, stainless steel |
| Flange Standard | DIN / ANSI / JIS / GB or customized |
| Control System | Manual, semi-automatic, or fully automatic control cabinet |
| Diesel Engine Option | Available for off-grid irrigation or field water transfer |
| Color and Nameplate | Custom branding support for distributors |
| Packaging | Export wooden case or project-specific packaging |
| OEM / ODM | Available for contractors, distributors, and project buyers |
Quality Control Before Delivery
For large-flow irrigation and clean water transfer projects, pump failure can delay water delivery and increase field operation cost. Pre-delivery inspection helps reduce installation risk and confirms that the pump matches the requested configuration.
| Inspection Item | What Should Be Checked | Buyer Value |
| Pump casing inspection | Casting quality, split-case surface, flange connection | Reduces leakage and installation issues |
| Impeller inspection | Balance, material, surface, clearance | Reduces vibration and efficiency loss |
| Shaft and bearing check | Alignment, rotation, bearing condition | Improves long-term stability |
| Seal inspection | Seal material and leakage condition | Reduces water leakage risk |
| Hydraulic performance test | Flow, head, pressure stability | Confirms duty point performance |
| Motor inspection | Voltage, power, insulation, rotation direction | Reduces electrical mismatch |
| Painting and surface check | Coating quality and corrosion protection | Improves outdoor durability |
| Packaging inspection | Nameplate, accessories, documents | Reduces shipping and installation confusion |
To reduce operational risk after installation, buyers can review this pump failure root cause diagnosis guide before confirming final operating conditions and maintenance planning.
Product Details
Common Mistakes When Buying a Double Suction Irrigation Pump
Many double suction pump problems are caused by incomplete working condition data or incorrect model selection. Buyers should confirm the full system requirement before choosing a pump.
Mistake 1: Choosing Only by Outlet Size
Outlet size does not equal flow capacity. Two pumps with the same outlet diameter may have different flow, head, efficiency, motor power, and operating range.
Mistake 2: Ignoring Pipeline Friction Loss
Large-flow systems can lose significant pressure through long pipelines, narrow pipe diameters, valves, elbows, and fittings. If friction loss is ignored, the pump may not deliver enough water at the final irrigation point.
Mistake 3: Using a Clean Water Pump for Muddy Water
This product is mainly for clean water or similar non-corrosive liquid. If the water contains heavy sand, mud, or abrasive particles, a slurry pump or another suitable pump should be considered.
Mistake 4: Oversizing the Pump
A larger pump is not always better. Oversizing may increase purchase cost, motor power, energy consumption, and operating instability if the pump runs far from its efficient range.
Mistake 5: Ignoring Maintenance Space
Double suction pumps require enough space for casing opening, bearing inspection, seal replacement, and lifting operations. If the pump room or station layout is too tight, maintenance will become difficult.
Frequently Asked Questions About Large Flow Double Suction Irrigation Pumps
This FAQ section answers common questions from buyers who need a large-flow double suction centrifugal pump for agricultural irrigation, clean water transfer, booster stations, river intake, reservoir pumping, and continuous water supply projects.
What is a double suction centrifugal pump used for?
A double suction centrifugal pump is used for large-flow clean water transfer, irrigation stations, municipal water supply, industrial cooling circulation, river intake, reservoir pumping, and booster systems. It is suitable when the project needs stable high flow and continuous operation.
Why choose a double suction pump for agricultural irrigation?
A double suction pump is suitable for agricultural irrigation when the project requires large flow, stable operation, and long daily running hours. Its double-suction impeller helps balance axial thrust and reduce vibration, making it more suitable for large irrigation stations than many small single-suction pumps.
Is this pump suitable for dirty or muddy water?
This pump is mainly suitable for clean water or similar non-corrosive liquids. If the water contains sand, mud, stones, or abrasive particles, buyers should add inlet screening or consider a slurry pump instead.
How do I choose the right flow rate?
The right flow rate depends on irrigation area, required water volume, irrigation method, and daily operating hours. Buyers should calculate how much water must be delivered per hour before selecting the pump.
How do I calculate the required head?
Required head includes static lift, pipeline friction loss, outlet pressure requirement, valve loss, elbow loss, and safety margin. For long-distance irrigation pipelines, friction loss can be significant and should not be ignored.
What is the difference between double suction pump and end suction pump?
A double suction pump is usually selected for larger flow and more stable continuous operation. An end suction pump is often more economical and compact for smaller or medium-flow water transfer systems.
Can the pump be used with a diesel engine?
Yes. For off-grid irrigation sites or field water transfer projects without stable electricity, the pump can be configured with a suitable diesel engine system after engineering confirmation.
Can voltage and control mode be customized?
Yes. Voltage, frequency, motor power, and control mode can be selected according to site conditions. Manual, semi-automatic, or fully automatic control cabinet options can be discussed based on project requirements.
What information should I provide before quotation?
Buyers should provide required flow rate, head, water source, water quality, pipeline length, pipe diameter, elevation difference, irrigation method, daily operating hours, voltage, frequency, and destination country.
Is MOQ available for sample testing?
Yes. MOQ can be 1 set for standard models, which is suitable for sample testing, replacement projects, and small-batch procurement.
What maintenance is required?
Regular maintenance includes checking bearing condition, seal leakage, vibration, noise, coupling alignment, motor temperature, foundation bolts, pipeline stress, and pump efficiency. During irrigation seasons, inspection should be scheduled before continuous operation.
How can I reduce energy consumption?
Energy consumption can be reduced by selecting the correct duty point, avoiding oversized pumps, using proper pipe diameter, reducing unnecessary elbows and valves, maintaining the pump regularly, and keeping the pump operating near its efficient range.
Get A Quote
After submitting your inquiry, you will receive an accurate quote within 2 hours.,We have a team of good service ready to support you in your business, you will get best services.
You can contact us by email. You may also submit your request. If you have any questions about the products, please feel free to contact us. We will try our best to solve your problem within 24 hours.
+8619933532256 (Wechat, Whatsapp)
No. 9 Ping'an North Street, Nan San Tiao Area, Chang'an District, Shijiazhuang City, Hebei Province, China